Japan Worldwide
News & EventsInvestorsProcurementCompany HomeContactsSite MapJapanese
Products & Support Automotive Process & Environmental Medical-Diagnostics Semiconductor Scientific Applications
Measurement Types
Product List
 HOME >> Products >> Analytical Instruments & Systems >> Carbon/Sulfur Analyzers
Analytical Instruments & Systems Products
product image
EMIA-V Series
Specifications

Carbon/Sulfur Analyzers
EMIA-V Series (High-Frequency Induction Furnace System)

Specifications
Models
EMIA-820V
EMIA-320V
EMIA-220V
Simultaneous carbon/sulfur analysis
EMIA-821V
EMIA-321V
EMIA-221V
Carbon analysis
EMIA-822V
EMIA-322V
EMIA-222V
Sulfur analysis
Analysis principles
Infrared light absorption during combustion in oxygen flow
(high-frequency furnace method)
Analysis range
Carbon: 0 to 6 wt%; Sulfur: 0 to 1 wt%, Up to 100% wt is possible by decreasing the sample weight.
Sample mass
1.0g standard
Analysis accuracy
(reprod-
ucibility)
*
Carbon
Analysis accuracyAnalysis accuracy Analysis accuracy
Sulfur
Analysis accuracyAnalysis accuracyAnalysis accuracy
Sensitivity
(minimum reading)
0.01ppm
0.1ppm
Analysis time
Normally 30 to 60 seconds(after start of combustion)
*Varies according to the characteristics of the sample.
Combustion furnace
method/furnace structure
circleHigh-frequency induction furnace method with combustion control function (patent pending)
Anode output: 2300W; frequency: 20MHz; plate current: settable up to 500mA; automatic control possible (10 slopes maximum)
circleConstant dust filter heating function
High-frequency furnace automatic cleaning mechanism
Built-in as standard
Option
No available
Oxygen gas purifying unit
Built-in as standard
Option
No available
Electronic scale
Option
External dimensions and mass
circleCombustion section
 W 560 x H 924 x D 906 mm, approximately 170kg
circleProcessing section
 W 360 x H 140 x D 248 mm, approximately 12kg
circleCombustion section
 W 579 x H 819 x D 912 mm, approximately 170kg
circleProcessing section
 W 360 x H 140 x D 248 mm, approximately 12kg
circleCombustion section
 W 579 xH 819 x D 912 mm, approximately 170kg
circleProcessing section
 W 360 x H 140 x D 248 mm, approximately 12kg

*Conditions for Analysis accuracy
circle With reliable steel standard samples recommended by HORIBA
circle With pre-burned HORIBA crucibles at 1000°C for longer than 30min
circle With oxygen carrier gas of purity greater than 99.5 vol% and THC (Total Hydrocabon) 1 volppm or less


TOP
Copyright (C) 2008 HORIBA, Ltd. All rights reserved.

Copyright © 2008 HORIBA, Ltd. All rights reserved. The information shown on this document may be modified without notice. Refer to the original web page for update. The page was copied from:
 
Explore the future HORIBA